S0845042

Spares kit, Caire 10LPM oxygen concentr


Spare parts kit for Caire NewLife Intensity 10 LPM oxygen concentrator (S0845038 and S0845033) maintenance and service, for use by trained technical staff. One kit recommended to be purchased with every 10 concentrators. The minimum quantities below are based on an estimated maintenance support period of 5 years.
Indicative Price 1,981.62 USD
Disclaimer: The images shown are for illustration purposes only and may not be an exact representation of the product. “No Generic Photo Available" means that there is not an image available for this product.

GENERAL DESCRIPTION
Spare parts kit for Caire NewLife Intensity 10 LPM oxygen concentrator(S0845038) maintenance and service, for use by trained technical staff. One kit recommended to be purchased with every 10 concentrators. The minimum quantities below are based on an estimated maintenance support period of 5 years.

SPECIFICATIONS
Note: Below listed spare parts are specifically for the Caire NewLifeIntensity 10 (single and dual flow) 10 LPM oxygen concentrators (S0845038 and S0845033). Reference numbers of the models are:
-230 Volt: single flow: AS099-103 / dual flow: AS099-10
-120 Volt: single flow: AS099-101 / dual flow: AS099-4

IMPORTANT: When ordering specify the manufacturer and whether the kit is to be used for a 120 Volt or 230 Volt model.

Part numbers and descriptions for 230 volts model
1 x Pressure regulator (RG088-1)
2 x Mains power cord (CD011-4 or CD011-18)
2 x Circuit breaker (CR001-6)
2 x Mains power switch (SW114-1)
2 x Flow meter for machine mounting (FM056-1)
6 x 6mm barbed oxygen outlet connector (F0025-1)
1 x DISS oxygen outlet connector (F0007-5)
Internal connecting pressure hose:
-- 2 x Green silicon tubing (2") (TU055-020S)
-- 2 x Green silicon tubing (3") (TU055-030S)
2 x Circuit board, fan power (CB164-2)
2 x Circuit board (CB200-2S)
2 x Oxygen monitor board (CB196-1)
4 x full sets of filters (internal and external):
-- 4 x Felt filter, intake resonator (MI161-2)
-- 4 x Filter inlet (FI002-1)
2 x Muffler (MU079-1S)
2 x Compressor service kit (CO012-11)
1 x Compressor assembly (CO306-2S)
6 x Solenoid valve assembly (VA001-2)
2 x Equalization valve (VA003-2)
4 x Check valve, sieve beds (VA543-1)
4 x Check valve, vacuum break (B/W) (VA006-2)
4 x Check valve, O2 outlet (clear) (VA142-3)
4 x Castor (single piece) (CS001-1S)
2 x Capacitor (CC012-7)
2 x Fan units (FN050-1)
2 x Humidifiers (HU014-1)

Part numbers and descriptions for 120 volts model
1 x Pressure regulator (RG088-1)
2 x Mains power cord (CD011-2)
2 x Circuit breaker (CR001-1)
2 x Mains power switch (SW114-1)
2 x Flow meter for machine mounting (FM056-1)
6 x 6mm barbed oxygen outlet connector (F0025-1)
1 x DISS oxygen outlet connector (F0007-5)
Internal connecting pressure hose:
-- 2 x Green silicon tubing (2") (TU055-020S)
-- 2 x Green silicon tubing (3") (TU055-030S)
2 x Circuit board, fan power (CB164-1)
2 x Circuit board (CB200-1S)
2 x Oxygen monitor board (CB196-1)
4 x full sets of filters (internal and external):
-- 4 x Felt filter, intake resonator (MI161-2)
-- 4 x Filter inlet (FI002-1)
2 x Muffler (MU079-1S)
2 x Compressor service kit (CO012-11)
1 x Compressor assembly (CO306-1S)
6 x Solenoid valve assembly (VA001-1)
2 x Equalization valve (VA003-1)
4 x Check valve, sieve beds (VA543-1)
4 x Check valve, vacuum break (B/W) (VA006-2)
4 x Check valve, O2 outlet (clear) (VA142-3)
4 x Castor (single piece) (CS001-1S)
2 x Capacitor (CC012-8)
2 x Fan units (FN050-1)
2 x Humidifiers (HU014-1)

ITEMS REQUIRED, BUT NOT SUPPLIED:
Tools to carry out the maintenance

WEIGHT AND VOLUME:
Weight: 16kg
Volume: 0.130m3

STORAGE CONDITIONS
Temperature: 0 °C to 40 °C,
Relative Humidity: 15% to 95% and elevation from 0 to at least 2000 m.

WARRANTY
Includes 90-day standard warranty, dated from the completion of the terms of delivery.

PACKAGING / LABELLING
Unit presentation: 1 (one)
Packing and labelling in compliance with the requirements as set out on the UNICEF Supply website under this hyperlink

For medical devices: Any symbol used on the labelling is in accordance with the ISO 15223-1:2016 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements.