S0845041

Oxygen concentrator, 5 LPM


A mains electricity powered device that concentrates oxygen from ambient air and delivers the concentrated oxygen in a controlled manner to a patient requiring oxygen therapy, up to 5 L/min.
Indicative Price 290.11 USD
Disclaimer: The images shown are for illustration purposes only and may not be an exact representation of the product. “No Generic Photo Available" means that there is not an image available for this product.

GENERAL DESCRIPTION
Oxygen concentrator, 5 LPM – single flow

IMPORTANT INFORMATION:
Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.

TECHNICAL SPECIFICATIONS
Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate of 5 L/min.
Contains oxygen monitor to verify concentration.
Equipped with one oxygen outlet, provided with controllable flowmeter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.
Flowmeter minimum flow rate of 1 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flowmeter stand (details under RELATED PRODUCTS).
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Contains flow limiter to prevent overdrawing oxygen flow beyond rated maximum flow rate.
Noise level <50 dB(A).

Casing and environment
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
Unit weight <27 kg
The unit includes internally and externally mounted filters for cleaning the air intake.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.

Electrical characteristics
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.

ITEMS SUPPLIED WITH
4 x adult cannula with 2m kink-resistant oxygen tubing with standard connectors.
4 x paediatric cannula with 2m kink-resistant oxygen tubing with standard connectors
1 x oxygen tubing, 15m
1 x humidifier bottle, reusable, up to 5LPM
Internal and external filters and spare parts (as described in user manual) for user fitting for 2 years’ operation at 15 hours per day, including
-1 x Gross particle filter
-1 x Intake filter
1 x User manual in local language, or in agreed other language if local is not available.
1 x List of equipment and procedures required for local cleaning, disinfection, troubleshooting, calibration and routine maintenance.
1 x List of all spares and accessories, with part numbers and contact details for parts supply.
1 x Document with contact details of manufacturer, supplier and local service agent.

ITEMS REQUIRED, BUT NOT SUPPLIED:
S0845030, Oxygen Analyzer, electrochem, handheld
S0845029, Oxygen Analyzer, ultrasonic, handheld

OPERATING CONDITIONS
- Temperature: 10 °C to 40 °C,
- Relative humidity: 15% to 90%
- Elevation above sea level: 0 to 2000m

STORAGE CONDITIONS
- Temperature: 0 °C to 40 °C,
- Relative humidity: 15% to 95%
- Elevation above sea level: 0 to 2000m

ESTIMATED LEAD TIME:
9 weeks

INSTALLATION REQUIREMENTS:
The User Manual supplied with the device details all installation which can be undertaken by users.

USER TRAINING REQUIREMENTS:
The User Manual supplied with the device details all operation procedures for user.

TECHNICAL TRAINING REQUIREMENTS:
The User Manual supplied with the device details all maintenance and troubleshooting procedures which can be undertaken by users.

MATERIAL SAFETY DATA SHEET INFORMATION (MSDS):
Not applicable.

WEIGHT AND VOLUME:
Weight 16.0 Kg
Volume0.099 M3

WARRANTY:
3 years

ALTERNATIVE PRODUCTS:
S0845195 Oxygen concentrator, 8LPM, single flow
S0845008 Oxygen concentrator, 8LPM, double flow
S0845038 Oxygen concentrator, 10 LPM, single flow
S0845033 Oxygen concentrator, 10 LPM, dual flow

RELATED PRODUCTS:
S0002031, Monitor,patient,portable,w/access
S0845014, Pulse oximeter,portable,w/access
S0845039, Flow splitter,for oxygen concentrator
S0845017, Pulse oximeter, handheld, incl.resp. rate
S0845013, Pulse oximeter,spot-check,waccess
S0002624, Pulse oximeter, tabletop
S0002632, Voltage stabilizer, 1 kVA
S0845049, Nasal Catheter, 8 Fr
S0845043, Tubing for patient oxygen supply
S0370105, Prongs,nasal,Oxygen,adult,s.u.
S0370115, Prongs,nasal,Oxygen,child,s.u.
S0370125, Prongs,nasal,Oxygen,neonate,s.u.
S0370130, Face mask, adult, venturi, single use
S0370131, Face mask, child, venturi, single use

ALTERNATIVE PRODUCTS:
S0002048, CPAP,bubble,medical,new-born
S0002019, Ventilator,medical,adult-child,w/access
S0002042, Ventilator,medical,new-born,w/access

PACKAGING/LABELLING
Unit presentation: 1 (one)
Labelling on primary packaging must include:
- Name and/or trademark of the manufacturer
- Manufacturer's product reference
- Type of product and main characteristics
- If the packaging is not transparent, it must bear a diagram showing the essential parts of the product
- Information for particular storage conditions (temperature, pressure, light, humidity, etc.), as appropriate (or equivalent harmonised symbol)
- Information for handling, if applicable (or equivalent harmonised symbol)

Over packaging: Packaging unit
Labelling on the packaging unit: Labelling to be the same as primary packaging